# P100-10AS

## Technical Resources

### Manual, Drivers, Datasheet

As a certified OnLogic solution, all detailed product documentation, including user manuals, technical specifications, regulatory information, and software downloads, is available directly on the manufacturer support site linked below.

{% embed url="<https://ipc.mitacmdt.com/IndustrialPanelPC_P100_P100-10AS>" %}

### Enabling Auto Power On

The system can be configured to turn on automatically when DC power is connected. This is useful for power outage recovery or if the unit is mounted in a hard to reach location. You can enable Auto Power On by following the steps listed below.

* Power up the system and press the F2/Del keys a few times to access the BIOS
* Navigate to the Chipset tab and locate the “Restore AC Power Loss” option
* Change it to \[power on]
* Press F10 to save and exit
* Auto power on is now enabled.

<figure><img src="/files/pz85fxvJzrlQTMRzYoKk" alt=""><figcaption></figcaption></figure>

<br>

## Troubleshooting

### **Clear CMOS** <a href="#clearing-the-cmos" id="clearing-the-cmos"></a>

If the system fails to power on or output video, clearing the CMOS can often help. To clear the CMOS, the system needs to be opened and an internal switch needs to be pressed.

Opening the system does not void the warranty, however, some precautions are necessary to avoid damaging the unit. Any damaged caused will not be covered by warranty.

* Perform this disassembly in an area free of static discharge
* Before beginning, touch a grounded metal surface to discharge your body of static electricity
* Power off and unplug the system. Disconnect all ports.
* Remove 2 screws from both short sides of the case – 4 screws total.

<figure><img src="/files/7VdXRZs9P17DjVrp73tI" alt=""><figcaption></figcaption></figure>

* Lift the screen and case apart.
* Use caution as cables will still be attached. Keep the two halves close.

<figure><img src="/files/ZSpVw2dedeYlj3FcMlbo" alt=""><figcaption></figcaption></figure>

* Locate the jumper blocks

<figure><img src="/files/zmB06Y6yVj9t8xfJl8XG" alt=""><figcaption></figcaption></figure>

* This is the default position.

<figure><img src="/files/h3mRVL332c51ILslk0b4" alt=""><figcaption></figcaption></figure>

* Move the outermost jumper over by 1 pin as shown

<figure><img src="/files/mhceydykp1qm4pkiINR9" alt=""><figcaption></figcaption></figure>

* Wait 30 seconds
* Restore the jumper to its original position.

<figure><img src="/files/0p8rhu3ZnmV1k1NuA4pj" alt=""><figcaption></figcaption></figure>

* The CMOS is now clear.
* Re-assemble the unit and power it on. Be patient as it may take several minutes to re-configure itself.
* If it is still non-responsive after 5 minutes, contact technical support.

### Security Advisory

For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.\
[**Access Security Advisories**](/support-articles/security-advisories.md)


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://support.onlogic.com/product-documentation/panel-products/panel-pcs-by-mitac/p100-10as.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.