M1101 Monitor Module
1
USB Cable
1
VGA Cable
1
Power Terminal Block Connector (Female)
1
Screw Pack
1




This page also applies to the TM400 ThinManager Ready platform.
As a certified OnLogic solution, all detailed product documentation, including user manuals, technical specifications, regulatory information, and software downloads, is available directly on the manufacturer support site linked below.
This article also applies to the TM400.
The P1001 can be opened by the user. This does not void the warranty, however, any damage caused by doing so will not be covered.
If you need an additional mating connector for your system’s power port, you can acquire our CBP123 component from our website, here.
The P1001 has two options for auto power on. In this section we will go over both with instructions.
The easiest and most reliable method of enabling auto power on for the P1001 is through the hardware, which uses the switch on the side of the unit. Slide the switch to AT mode to enable auto power on.
The downside of this method is that the power button is completely disabled. If you manually shut down the PC, you will need to cycle power to restart it. If that is an issue for your use case, use option 2 instead.
Power on the system and immediately press the Del key a few times to access the BIOS
Navigate over to the Chipset tab and open the South Bridge menu
Change the option Restore AC Power Loss to [Power On]
Navigate to the Save & Exit tab and choose “Save Changes and Reset”
Required tools: T10 Torx Driver
Disconnect the unit from all connections (power, USB, ethernet, etc.)
Remove the 8x torx screws that hold the lid in place
Lift the lid off vertically. Moderate force may be required to break the thermal seal.
Set the lid aside
The CMOS battery and CMOS reset switch are now exposed. The CMOS can be cleared by moving the blue switch to the ON position for 30 seconds
The CMOS has now been cleared
Reinstall the top cover and the torx screws
NOTE: The unit may power cycle several times before it boots up. This is normal.
For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.







As a certified OnLogic solution, all detailed product documentation, including user manuals, technical specifications, regulatory information, and software downloads, is available directly on the manufacturer support site linked below.
The P2102 series has two options for auto power on. The easiest and most reliable method is to use the hardware switch underneath the maintenance panel. The downside of this method is that the power button is completely disabled. If you shut down the PC, you will need to cycle power to restart it. If that is an issue for your use case, use option 2 instead.
Remove the Torx T10 screw from the front maintenance panel.
Remove the panel
Locate the AT ATX switch
Slide the switch to AT mode for auto power on, slide to ATX to disable auto power on
Power on the system and immediately press the Del key a few times to access the BIOS.
Navigate over to the Chipset tab and open the PCH-IO configuration menu.
Change the Power Failure option to the desired setting
Navigate to the Save & Exit tab and choose “Save Changes and Reset”
Unplug the unit completely from power. Unplug all devices.
Remove the Torx T10 screw from the front maintenance panel.
Remove the panel
Locate the clear CMOS switch
Slide the switch to rightmost position and wait 30 seconds
Slide the switch back to the left position
Reinstall the panel and power on the unit
For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.
The CMOS is now clear. Several reboots are normal as the CMOS reinitializes.
[Always on]: Enables auto power on.
[Always off]: Disables auto power on.
[Keep last state]: Auto power on only if the unit was already on. 




This page also applies to the TM410 ThinManager Ready platform.
This page also applies to the IGN310 Ignition Software and TM410 ThinManager Ready platform
As a certified OnLogic solution, all detailed product documentation, including user manuals, technical specifications, regulatory information, and software downloads, is available directly on the manufacturer support site linked below.
The P1101 has two options for auto power on. In this section we will go over both with instructions.
The easiest and most reliable method of enabling auto power on for the P1101 is through the hardware, which uses the switch underneath the panel.
Remove the two Torx T10 screws
Slide the AT/ATX switch to the AT position. AT enables auto power on.
The downside of this method is that the power button is completely disabled. If you manually shut down the PC, you will need to cycle power to restart it. If that is an issue for your use case, use option 2 instead.
Power on the system and immediately press the Del key a few times to access the BIOS
Navigate over to the Chipset tab and open the South Bridge menu
Change the option Restore AC Power Loss to [Power On]
Navigate to the Save & Exit tab and choose “Save Changes and Reset”
The P1101 can be opened by the user. This does not void the warranty, however, any damage caused by doing so will not be covered. Some precautions should be taken to avoid damaging the unit:
Perform this disassembly in an area free of static discharge
Before beginning, touch a grounded metal surface to discharge your body of static electricity
Remove x8 screws from the back/top of the system as indicated. You will need a Torx T10 screwdriver.
Remove the heatsink lid to gain access to the motherboard.
If the system fails to power on or otherwise function, clearing the CMOS may help restore it to a working state.
Required tools: T10 Torx driver
Remove the two Torx T10 screws
Slide the Clear CMOS switch to the other position
Wait 30 seconds
Return the switch to its original position
The CMOS is now clear
NOTE: The unit may power cycle several times before it boots up. This is normal.
For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.






As a certified OnLogic solution, all detailed product documentation, including user manuals, technical specifications, regulatory information, and software downloads, is available directly on the manufacturer support site linked below.
The P1301 has two options for auto power on. In this section we will go over both with instructions.
The easiest and most reliable method of enabling auto power on for the P1301 is through the hardware, which uses the switch underneath the panel.
Remove the Torx T10 screw
Slide the AT/ATX switch to the AT position. AT enables auto power on.
The downside of this method is that the power button is completely disabled. If you manually shut down the PC, you will need to cycle power to restart it. If that is an issue for your use case, use option 2 instead.
Power on the system and immediately press the Del key a few times to access the BIOS
Navigate over to the Chipset tab and open the PCH-IO Configuration menu
Change the Power Failure option to [Power on]
Navigate to the Save & Exit tab and choose “Save Changes and Reset”
The P1301 can be opened by the user. This does not void the warranty, however, any damage caused by doing so will not be covered. Some precautions should be taken to avoid damaging the unit:
Perform this disassembly in an area free of static discharge
Before beginning, touch a grounded metal surface to discharge your body of static electricity
Remove x8 screws from the back/top of the system as indicated. You will need a Torx T10 screwdriver.
If the system fails to power on or otherwise function, clearing the CMOS may help restore it to a working state.
Required tools: T10 Torx driver
After disconnecting the unit from all power and peripherals remove the Torx T10 screw
Slide the Clear CMOS switch to the other position
Wait 30 seconds
Return the switch to its original position
The CMOS is now clear
NOTE: The unit may power cycle several times before it boots up. This is normal.