All pages
Powered by GitBook
1 of 6

Loading...

Loading...

Loading...

Loading...

Loading...

Loading...

M1001 / M1101

Technical Resources

Datasheets & Manuals for Cincoze Monitors

As a certified OnLogic solution, all detailed product documentation, including user manuals, technical specifications, regulatory information, and software downloads, is available directly on the manufacturer support site linked below.

12" Cincoze Monitor
M1101 Module
CV-100C-M1101
Panel mounting clips included in standard accessories

Package Contents

Description
Quantity

If you need an additional mating connector for your system’s power port, you can acquire our CBP123 component from our website, .

For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.

M1101 Monitor Module

1

USB Cable

1

VGA Cable

1

Power Terminal Block Connector (Female)

1

Screw Pack

1

Panel PC Mounting Guide

Replacement Power Connector

Security Advisory

here
Access Security Advisories
Cincoze-Panel-PC-Mounting-Guide.pdf
PDF · 375KB
Open
Monitor Module (M1000 Series) | Convertible Embedded System | Products | Cincozewww.cincoze.com
Logo
M1000 Convertible Monitor Modulewww.cincoze.com
Logo

CV-P1001 / CS-P1001

This page also applies to the TM400 ThinManager Ready platform.

Technical Resources

Manual, Drivers, Datasheet

As a certified OnLogic solution, all detailed product documentation, including user manuals, technical specifications, regulatory information, and software downloads, is available directly on the manufacturer support site linked below.

This article also applies to the TM400.

Disassembly

The P1001 can be opened by the user. This does not void the warranty, however, any damage caused by doing so will not be covered.

Replacement Power Connector

If you need an additional mating connector for your system’s power port, you can acquire our CBP123 component from our website, here.

How to Enable Auto Power On for P1001

The P1001 has two options for auto power on. In this section we will go over both with instructions.

Option 1: Hardware

The easiest and most reliable method of enabling auto power on for the P1001 is through the hardware, which uses the switch on the side of the unit. Slide the switch to AT mode to enable auto power on.

The downside of this method is that the power button is completely disabled. If you manually shut down the PC, you will need to cycle power to restart it. If that is an issue for your use case, use option 2 instead.

  1. Power on the system and immediately press the Del key a few times to access the BIOS

  2. Navigate over to the Chipset tab and open the South Bridge menu

  3. Change the option Restore AC Power Loss to [Power On]

  4. Navigate to the Save & Exit tab and choose “Save Changes and Reset”

Required tools: T10 Torx Driver

  1. Disconnect the unit from all connections (power, USB, ethernet, etc.)

  2. Remove the 8x torx screws that hold the lid in place

  1. Lift the lid off vertically. Moderate force may be required to break the thermal seal.

  1. Set the lid aside

  1. The CMOS battery and CMOS reset switch are now exposed. The CMOS can be cleared by moving the blue switch to the ON position for 30 seconds

  1. The CMOS has now been cleared

  2. Reinstall the top cover and the torx screws

NOTE: The unit may power cycle several times before it boots up. This is normal.

For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.

Option 2: BIOS

Troubleshooting

Clear CMOS for P1001

Security Advisory

Access Security Advisories

CV-P2102 / CS-P2102

Technical Resources

Manual, Drivers, Datasheet

As a certified OnLogic solution, all detailed product documentation, including user manuals, technical specifications, regulatory information, and software downloads, is available directly on the manufacturer support site linked below.

Auto Power On

The P2102 series has two options for auto power on. The easiest and most reliable method is to use the hardware switch underneath the maintenance panel. The downside of this method is that the power button is completely disabled. If you shut down the PC, you will need to cycle power to restart it. If that is an issue for your use case, use option 2 instead.

Option 1: Hardware

  • Remove the Torx T10 screw from the front maintenance panel.

  • Remove the panel

  • Locate the AT ATX switch

  • Slide the switch to AT mode for auto power on, slide to ATX to disable auto power on

  • Power on the system and immediately press the Del key a few times to access the BIOS.

  • Navigate over to the Chipset tab and open the PCH-IO configuration menu.

  • Change the Power Failure option to the desired setting

  • Navigate to the Save & Exit tab and choose “Save Changes and Reset”

  • Unplug the unit completely from power. Unplug all devices.

  • Remove the Torx T10 screw from the front maintenance panel.

  • Remove the panel

  • Locate the clear CMOS switch

  • Slide the switch to rightmost position and wait 30 seconds

  • Slide the switch back to the left position

  • Reinstall the panel and power on the unit

For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.

The CMOS is now clear. Several reboots are normal as the CMOS reinitializes.

 [Always on]: Enables auto power on. 
 [Always off]: Disables auto power on. 
 [Keep last state]: Auto power on only if the unit was already on. 

Option 2: BIOS

Clear the CMOS

Security Advisory

Access Security Advisories

CV-P1101 / CS-P1101

This page also applies to the TM410 ThinManager Ready platform.

Technical Resources

This page also applies to the IGN310 Ignition Software and TM410 ThinManager Ready platform

Manual, Drivers, Datasheet

As a certified OnLogic solution, all detailed product documentation, including user manuals, technical specifications, regulatory information, and software downloads, is available directly on the manufacturer support site linked below.

Enabling Auto Power On

Internal Access

Troubleshooting

Enabling Auto Power On

The P1101 has two options for auto power on. In this section we will go over both with instructions.

Option 1: Hardware

The easiest and most reliable method of enabling auto power on for the P1101 is through the hardware, which uses the switch underneath the panel.

  1. Remove the two Torx T10 screws

  1. Slide the AT/ATX switch to the AT position. AT enables auto power on.

The downside of this method is that the power button is completely disabled. If you manually shut down the PC, you will need to cycle power to restart it. If that is an issue for your use case, use option 2 instead.

  1. Power on the system and immediately press the Del key a few times to access the BIOS

  2. Navigate over to the Chipset tab and open the South Bridge menu

  3. Change the option Restore AC Power Loss to [Power On]

  4. Navigate to the Save & Exit tab and choose “Save Changes and Reset”

The P1101 can be opened by the user. This does not void the warranty, however, any damage caused by doing so will not be covered. Some precautions should be taken to avoid damaging the unit:

  • Perform this disassembly in an area free of static discharge

  • Before beginning, touch a grounded metal surface to discharge your body of static electricity

Remove x8 screws from the back/top of the system as indicated. You will need a Torx T10 screwdriver.

Remove the heatsink lid to gain access to the motherboard.

If the system fails to power on or otherwise function, clearing the CMOS may help restore it to a working state.

Required tools: T10 Torx driver

  1. Remove the two Torx T10 screws

  1. Slide the Clear CMOS switch to the other position

  2. Wait 30 seconds

  3. Return the switch to its original position

  4. The CMOS is now clear

NOTE: The unit may power cycle several times before it boots up. This is normal.

For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.

Option 2: BIOS

Internal Access

Clear CMOS on P1101

Security Advisory

Access Security Advisories

CV-P1301 / CS-P1301

Technical Resources

Manual, Drivers, Datasheet

As a certified OnLogic solution, all detailed product documentation, including user manuals, technical specifications, regulatory information, and software downloads, is available directly on the manufacturer support site linked below.

Enabling Auto Power On

The P1301 has two options for auto power on. In this section we will go over both with instructions.

Option 1: Hardware

The easiest and most reliable method of enabling auto power on for the P1301 is through the hardware, which uses the switch underneath the panel.

  1. Remove the Torx T10 screw

  1. Slide the AT/ATX switch to the AT position. AT enables auto power on.

The downside of this method is that the power button is completely disabled. If you manually shut down the PC, you will need to cycle power to restart it. If that is an issue for your use case, use option 2 instead.

  1. Power on the system and immediately press the Del key a few times to access the BIOS

  2. Navigate over to the Chipset tab and open the PCH-IO Configuration menu

  3. Change the Power Failure option to [Power on]

  4. Navigate to the Save & Exit tab and choose “Save Changes and Reset”

The P1301 can be opened by the user. This does not void the warranty, however, any damage caused by doing so will not be covered. Some precautions should be taken to avoid damaging the unit:

  • Perform this disassembly in an area free of static discharge

  • Before beginning, touch a grounded metal surface to discharge your body of static electricity

Remove x8 screws from the back/top of the system as indicated. You will need a Torx T10 screwdriver.

If the system fails to power on or otherwise function, clearing the CMOS may help restore it to a working state.

Required tools: T10 Torx driver

  1. After disconnecting the unit from all power and peripherals remove the Torx T10 screw

  1. Slide the Clear CMOS switch to the other position

  2. Wait 30 seconds

  3. Return the switch to its original position

  4. The CMOS is now clear

NOTE: The unit may power cycle several times before it boots up. This is normal.

If you need an additional mating connector for your system’s power port, you can acquire our CBP123 component from our website, .

For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.

Option 2: BIOS

Troubleshooting

Internal Access

Clear CMOS on P1301

Replacement Power Connector

Security Advisory

here
Access Security Advisories
Entry Performance Computer Module (P1000 Series) | Convertible Embedded System | Products | Cincozewww.cincoze.com
Logo
Entry Performance Computer Module (P1000 Series) | Convertible Embedded System | Products | Cincozewww.cincoze.com
Logo
Entry Performance Computer Module (P1000 Series) | Convertible Embedded System | Products | Cincozewww.cincoze.com
Logo

Panel PCs by Cincoze

High Performance Computer Module (P2000 Series) | Convertible Embedded System | Products | Cincozewww.cincoze.com
Logo