FR101 Industrial Computer Product Manual
The OnLogic FR101 computer harnesses the advanced power and integrated edge AI capabilities of the Qualcomm QCS6490 Integrated ARM CPU. This is a versatile AI computing device capable of delivering AI inference capabilities in a fanless, industrial design. Engineered for the evolved edge, with a 0ยฐC to 50ยฐC operating temperature range, the FR101 thrives in a diverse range of industrial applications. The Qualcomm Dragonwingโข QCS6490 processor is purpose-built for high-performance edge computing, combining up to 8-core Qualcommยฎ Kryoโข CPUs, integrated Qualcommยฎ Adrenoโข GPU, and a powerful AI engine (NPU + DSP), delivering up to 12 dense TOPS. These platforms enable real-time, on-device processing for compute-intensive applications like autonomous robotics, smart vision, and industrial automation.
For more information on accessories and additional features, visit the FR101 product page:
1x 19V Power Supply
1x 16-pin DIO Terminal Block
All drivers and product guides can be found on the corresponding product page. For more information on accessories and additional features, visit the FR101 Product Page:
Button Defintions:
Status LED
Mainboard power is applied to the Factor 101 platform by way of a female barrel jack connector. The system is operational at 19V DC.
A USB 3.0 Type-C port is provided for peripheral usage and as an additional display output option through Display Port over USB-C. Additionally, the port is used for accessing the system via ADB (Android Debug Bridge). See for more information on flashing an operating system through the ADB port.
4 USB 3.0 Type-A ports are provided for peripheral usage.
The first LAN port on FR101 supports up to 1Gbps link speeds over standard shielded CAT5e or CAT6 cables. The connector is the industry standard RJ45 connector. The LAN link state is shown by the two LEDs enclosed in the port.
The second LAN port on FR101 supports up to 10Gbps link speeds over standard shielded CAT5e or CAT6 cables. The connector is the industry standard RJ45 connector. The LAN link state is shown by the two LEDs enclosed in the port.
The FR101 uses the Qualcomm QPS615 Ethernet-AVB/TSN bridge IC for high-speed interfacing between the host SoC and ethernet devices on the network. Connection to the host is via 2 lanes of PCIe Gen3.
In Ubuntu 20.04, resolutions up to 1920x1080 @ 60Hz are supported. In case of interoperability issues between certain monitors and the FR101, connect the HDMI to the external display before powering on the system.
The definitions of the digital input/output ports are shown below:
The digital input/output ports can be controlled through Linux sysfs, or via gpiod on gpiochip5.
Example of a digital input port:
Example of a digital output port:
Digital output port reference schematic (open drain/isolation):
The digital output port can drive relay coils with specifications of 12V/24V/40V, with a current limit of 150mA.
The FR101 supports an input voltage range of 12V-24V. However, to guarantee optimal performance, OnLogic recommends the use of the provided 19V/65W power supply. The approximate maximum power draw of the system under load is about 60W.
The FR101 supports wall mounting using the integrated mounting brackets.
OnLogic does not recommend accessing the internals of the FR101 though the removal of any outer plate.
The FR101 supports the distribution of Ubuntu 24.04 for Qualcomm Dragonwing IoT, with kernel 6.8.0-1080-qcom, build 89.qc01w. On first boot, the default user name is "ubuntu", and the default password is "ubuntu". The operating system, modified with the supported kernel, can be downloaded below:
The FR101 will arrive imaged with a minimal Ubuntu 20.04 desktop environment. The default user name and password combination is onlogic/onlogic. The default root password is oelinux123, and the user may switch to root mode using su.
When booting into the operating system directly from the FR101, ensure that "Ubuntu on Wayland" is selected from the bottom right gear icon at login, shown below:
Android debug bridge is a command line tool used for accessing the FR101 system over USB-C for moving files, installing packages, or debugging applications. For more information on installation and use, refer to the official .
ADB is not supported on Ubuntu 24.04. The recommended way to remotely access the system is over ssh.
To reflash the system image, the device must enter Force USB Recovery mode to transfer the system image file from a PC/Laptop. The steps to enter EDL (Emergency Download Mode) mode are as follows:
Unplug all wires from the FR101 and unplug the USB cable from the imaging device.
Hold down the FN2 button with a paper clip.
While holding FN2, plug in power to the FR101. Wait 2-3 seconds then remove the paper clip.
Plug the USB-C cable in to the FR101.
The FR101 supports flashing the integrated UFS via the USB-C port. To re-flash the operating system, first follow the instructions to put the FR101 into .
From a separate Windows PC or laptop:
Attach a USB cable to the USB-C port on the FR101. Verify the QDL port is present by opening device manager, and expanding the "Ports" section.
Download and extract the Ubuntu 24.04 or 20.04 image directory.
Ubuntu 24.04: From the extracted folder structure, run _Burn_Image_AIBO.bat
Once flashing is complete, the tool will automatically reboot the FR101.
For installing additional packages standard to an Ubuntu desktop experience, proceed with the following:
Navigate to 20.04_onlogic/ubuntu/image/
On your Windows imaging device, run ubuntu_preseed.bat
Allow the script to complete and reboot the system upon success. You will be met with the Ubuntu login screen requiring the same default passwords and display environment selection mentioned in .
Storage
128GB UFS Flash
Networking
Ethernet support through QPS615
Right I/O
1x Status LED 1x Power Button 1x Recovery Button 1x Reset Button 1x Function Button
Front I/O
1x 1GbE LAN (RJ45) 1x 10GbE LAN (RJ45) 4x USB 3.0 Type-A 1x USB 3.0 Type-C 1x HDMI 1x Barrel Jack Power DC 19V
Rear I/O
Digital In/Digital Output (4 DI ports (5V) & 4 DO ports)
Voltage Input
19 VDC
Operating Systems
Ubuntu 24.04, Ubuntu 20.04
Operating Temperature
0ยฐC to 50ยฐC
Regulatory
FCC Part 15 Class A
EN 63268-1 CISPR 32/EN 55032 CISPR 35/EN 55035 RoHS 3 Directive (2015/863/EU)
WEEE Directive (2012/19/EU)
Countries
US, Canada, UK, EU, Japan, South Korea, Australia, New Zealand, China, India, Mexico, Brazil, Singapore, Hong Kong, Saudi Arabia, UAE
FN3 Button
Send hotkey code (Kcode: F3)
DI 4
730
7
DO 1
723
0
DO 2
724
1
DO 3
725
2
DO 4
726
3
DI 1
297
4
DI 2
298
5
DI 3
299
Ubuntu 20.04: Navigate to 20.04_onlogic/image/QFIL_flat/ufs/ and run _Burn_image.bat.
If prompted, select option "1b".
Read the entire manual before using the product.
Install the device securely per users manual instructions.
Wall or ceiling mounting device requires use of OnLogic mounting plate or bracket.
Use M3x0.5mm Flat Head screws to attach mounting plate or mounting brackets to threaded holes on bottom or rear of chassis. Screws should be a minimum length of 4mm. Add 1mm of screw length for every mm of additional thickness of plate or bracket beyond 1.5mm.
Caution, Hot Surface! It is normal for the unit to heat up and be hot to touch. Do not touch the heatsink area or enclosure during operation and 30 minutes after shutdown allowing the unit to cool down.
Ambient operating temperature must be between -20 ยฐC to 60 ยฐC with a non-condensing relative humidity of 10-85%.
The device can be stored at temperatures between -20 ยฐC to 85 ยฐC. Note: Unit must be stabilized within operating temperature before use, minimum 3HR.
Keep the device away from liquids and flammable materials. Not to be installed in a hazardous environment.
Do not clean the device with liquids. The chassis can be cleaned with a dry cloth or duster only. To prevent injury to self and/or damage to the device the unit must be powered down and all connecting power and other peripherals shall be disconnected prior to cleaning.
Allow adequate space around all sides of the device for proper cooling and to not exceed its maximum operating temperature limit. If the device is mounted to a vertical surface then recommended device orientation is such that heatsink fins allow air to rise unobstructed. Alternative orientations may result in reduced operational temperature range.
This device is intended for indoor operation only.
Caution, Risk of Electric Shock! Unit is powered by low voltage DC (Direct Current) only! Do not connect AC (Alternating Current) into the device!
To power the device use only UL ITE Listed external power supplies with DC output of 12-24VDC, see specs for details.
Install the device only with shielded network cables.
The installer should be experienced in aftermarket installation and familiar with general practices for installing electronics.
Service and repair of the device must be done by qualified skilled service personnel. This includes, but is not limited to, replacement of the CMOS battery. Replacement CMOS battery must be UL recognized and of a similar type as the original.
Proper disposal of the CMOS battery must comply with local governance.
This equipment is not suitable for use in locations where children are likely to be present.
WARNING: There is danger of explosion if the CMOS battery is replaced incorrectly. Disposal of battery into fire or a hot oven, or mechanically crushing or cutting of a battery can result in an explosion.
Lisez l'intรฉgralitรฉ du manuel avant d'utiliser le produit.
Installez l'appareil en toute sรฉcuritรฉ selon les instructions du manuel de l'utilisateur.
Pour vous protรฉger contre une exposition RF excessive, maintenez au moins 20 cm de tout utilisateur et des antennes RF. Utilisez uniquement les antennes double bande fournies avec un gain de 2 dBi/2 dBi.
Le dispositif de montage mural ou au plafond nรฉcessite l'utilisation d'une plaque ou d'un support de montage. La plaque ou le support doit รชtre en mรฉtal et avoir une รฉpaisseur minimale de 1 mm.
Utilisez des vis ร tรชte plate M4x0,5 mm pour fixer la plaque de montage ou les supports de montage aux trous filetรฉs au bas ou ร l'arriรจre du chรขssis. Les vis doivent avoir une longueur minimale de 4 mm. Ajoutez 1 mm de longueur de vis pour chaque mm d'รฉpaisseur supplรฉmentaire de plaque ou de support au-delร de 1,5 mm.
Attention surface chaude! Il est normal que l'appareil chauffe et soit chaud au toucher. Ne touchez pas la zone du dissipateur thermique ou le boรฎtier pendant le fonctionnement et 30 minutes aprรจs l'arrรชt pour permettre ร l'unitรฉ de refroidir.
La tempรฉrature ambiante de fonctionnement doit รชtre comprise entre -20 ยฐC et 60 ยฐC avec une humiditรฉ relative sans condensation de 10 ร 85 %.
L'appareil peut รชtre stockรฉ ร des tempรฉratures comprises entre -20 ยฐC et 85 ยฐC. Remarque : L'unitรฉ doit รชtre stabilisรฉe ร la tempรฉrature de fonctionnement avant utilisation, minimum 3 heures.
Gardez l'appareil ร l'รฉcart des liquides et des matรฉriaux inflammables. Ne pas installer dans un environnement dangereux.
Ne nettoyez pas l'appareil avec des liquides. Le chรขssis peut รชtre nettoyรฉ uniquement avec un chiffon sec ou un plumeau. Pour รฉviter de se blesser et/ou d'endommager l'appareil, l'appareil doit รชtre รฉteint et toutes les alimentations et autres pรฉriphรฉriques doivent รชtre dรฉconnectรฉs avant le nettoyage.
Prรฉvoyez un espace suffisant autour de tous les cรดtรฉs de l'appareil pour un refroidissement correct et pour ne pas dรฉpasser sa limite de tempรฉrature de fonctionnement maximale. Si l'appareil est montรฉ sur une surface verticale, l'orientation recommandรฉe de l'appareil est telle que les ailettes du dissipateur thermique permettent ร l'air de monter sans obstruction. Des orientations alternatives peuvent entraรฎner une plage de tempรฉratures de fonctionnement rรฉduite.
Cet appareil est destinรฉ ร une utilisation en intรฉrieur uniquement.
Attention, risque de choc รฉlectrique ! L'unitรฉ est alimentรฉe uniquement par une basse tension CC (courant continu) ! Ne connectez pas le courant alternatif (courant alternatif) ร l'appareil !
Pour alimenter l'appareil, utilisez uniquement des alimentations externes rรฉpertoriรฉes UL ITE avec une sortie CC de 12-24 VCC, voir les spรฉcifications pour plus de dรฉtails.
Les mรฉthodes de cรขblage utilisรฉes pour le raccordement de l'รฉquipement ร l'alimentation secteur doivent รชtre conformes au Code national de l'รฉlectricitรฉ, NFPA 70, et au Code canadien de l'รฉlectricitรฉ, Partie I, CSA C22.1.
Prรฉvoyez suffisamment d'espace pour les connexions de cรขblage du bornier afin que les fils ne se plient pas et soient protรฉgรฉs contre les dommages accidentels.
Installez l'appareil uniquement avec des cรขbles rรฉseau blindรฉs.
L'installateur doit avoir de l'expรฉrience dans l'installation de piรจces de rechange et รชtre familiarisรฉ avec les pratiques gรฉnรฉrales d'installation de composants รฉlectroniques.
L'appareil radio n'est pas destinรฉ aux services d'urgence.
L'entretien et la rรฉparation de l'appareil doivent รชtre effectuรฉs par un personnel qualifiรฉ. Cela inclut, mais sans s'y limiter, le remplacement de la batterie CMOS. La batterie CMOS de remplacement doit รชtre du mรชme type que celle d'origine.
L'รฉlimination appropriรฉe de la batterie CMOS doit รชtre conforme ร la gouvernance locale.
Le produit doit uniquement รชtre connectรฉ ร un routeur, un commutateur ou un รฉquipement rรฉseau similaire certifiรฉ
Le produit est destinรฉ ร une utilisation en intรฉrieur uniquement.
Le produit ne peut pas รชtre connectรฉ au rรฉseau public.
Cet รฉquipement n'est pas adaptรฉ ร une utilisation dans des endroits oรน des enfants sont susceptibles d'รชtre prรฉsents.
ATTENTION: Il existe un risque d'explosion si la pile CMOS n'est pas remplacรฉe correctement. L'รฉlimination de la batterie dans le feu ou dans un four chaud, ou l'รฉcrasement ou le dรฉcoupage mรฉcanique d'une batterie peut entraรฎner une explosion.
System Dimensions
94mm x 157mm x 70.75mm 530 g
CPU
8-Core Qualcommยฎ Kryoโข 670 Up to 2.1 GHz
GPU
Qualcommยฎ Adrenoโข 643
AI Performance
Qualcommยฎ Hexagonโข 770
Up to 12 Dense TOPS (Tera Operations Per Second)
Memory
Power Button (Press)
Software Shutdown (Ubuntu 20.04 only)
Power Button (Hold - 8 sec)
Reset (Reboot)
FN1 Button (Press)
Send hotkey code (Kcode: F1)
FN1 Button (Hold - 8 sec)
Hardware shutdown (Reboots if connected to USB-C)
FN2 Button
Send hotkey code (Kcode: F2)
System off with power
Dark
Booting
Steady Blue
Power on and ready
Steady Teal
DI 1
727
4
DI 2
728
5
DI 3
729
# sysfs
echo 727 > /sys/class/gpio/export
echo in > /sys/class/gpio/gpio727/direction
cat /sys/class/gpio/gpio727/value
echo 727 > /sys/class/gpio/unexport
# gpiod
gpioget gpiochip5 4# sysfs
echo 723 > /sys/class/gpio/export
echo out > /sys/class/gpio/gpio723/direction
echo 1 > /sys/class/gpio/gpio723/value
echo 0 > /sys/class/gpio/gpio723/value
echo 723 > /sys/class/gpio/unexport
# gpiod
gpioset gpiochip5 0=1
gpioset gpiochip5 0=0














8GB LPDDR4x
6
6
DI 4
300
7
DO 1
293
0
DO 2
294
1
DO 3
295
2
DO 4
296
3