BIOS Version 1.04
The UEFI BIOS is a small program which runs when your computer starts and configures its basic functions. That configuration is automatic, and most users will be satisfied with the default configuration. If the default configuration is not sufficient, the BIOS has setup menus which can be used to reconfigure the computer.
The purpose of this manual is to document the function of the BIOS and its available configuration options. The text of this document lists the BIOS menus and options exactly as they appear in the BIOS menus: in the correct order, with the correct default values for this BIOS version. Some options are hidden based on how other options are set and which hardware is detected in the system, so some options may not appear on all systems. Informative screenshots are also provided throughout, but their contents may not exactly match this BIOS version.
To access the BIOS setup menu, hold the DEL key on the keyboard while turning on the system. After a few seconds, the BIOS front page menu is shown:
On each menu, the selected option is shown in white, other options are shown in blue, and read-only options are shown in gray. Some menus have multiple screens, which are shown at the top of the screen. The active screen is shown with a gray background and inactive screens are shown with blue backgrounds.
BIOS menus are navigated by pressing keys on the keyboard:
F1 shows help on available keyboard shortcuts
↑/↓ arrow keys select the option above or below the currently-selected option
→/← arrow keys activate the screen to the right or left of the currently-activated screen
To access the BIOS boot manager, hold the F10 key on the keyboard while turning on the system. After a few seconds, the BIOS boot manager is shown:
To access the Secure Boot Menu, hold the Ctrl+Alt+F4 key on the keyboard while turning on the system. After a few seconds, the Secure Boot menu is shown:
The system will prompt you to set admin passwords to configure secure boot for the first time.
Enter the admin password to access the secure boot setting page.
The Error LED is effectively controlled by BIOS based on the following conditions:
Blinking frequencies:
Slow blinking: 0.5 Hz (Blinks once every two seconds)
Medium blinking: 1 Hz (Blinks once every second)
Fast blinking: 4 Hz (Blinks four times every second)
When RTC battery is low, BIOS will display "Warning: Low RTC battery" for 30 seconds during the BIOS POST.
If a BIOS update is interrupted, your system may fail to boot. The system will attempt to recover in two ways:
1. Automatic Recovery
The system will automatically try to restore the original BIOS image.
Look for the text "Crisis Recovery" on your screen.
This indicates the repair is in progress.
2. Manual Recovery (USB Method)
If the system keeps rebooting and does not recover automatically, follow these steps:
Save a valid BIOS image file onto a USB flash drive.
Rename the file to: CL260.bin
Insert the USB drive into the computer.
You can enable the Factory Reset Button under Onlogic Feature Configuration of the BIOS setup menu
Turn off the system completely.
Press and hold the Factory Reset button.
While still holding Reset, press the Power button to turn the system on.
Wait 5 seconds after the system powers up, then release the Factory Reset button.
The Result:
All BIOS settings return to default.
Admin passwords are deleted.
SSD S.M.A.R.T Health Check is enabled by default in the Onlogic Feature Configuration
BIOS will check the SSD health status and display warnings if the status is bad for 30 seconds
Normal Operation: Once the computer boots to an OS, the BIOS constantly resets a hidden countdown timer to prove the system is still running smoothly.
If the system freezes ("hangs") and stops working, it fails to reset that timer.
When the timer runs out (hits zero), it automatically forces the computer to restart to recover from the freeze.
To enable In-Band ECC in the memory configuration page, Intel Trusted Execution Technology must be disabled in the CPU configuration page.
Several options are available on the Main page:
Platform information: a comprehensive summary of the computer's hardware components and firmware details
Language: Select which language to display
System Time: adjust RTC time
System Date: adjust RTC date
The Advanced menu contains the following options:
BT
Enable/Disable BT module
WIFI
Enabling Turbo Mode on the CL260 Description By default, Turbo Mode is disabled in the shipping BIOS to prevent total power consumption from exceeding the maximum output of the power adapter, particularly when Power over Ethernet (PoE) is utilized to power external devices.
If you are not using PoE as a power source, you may follow the instructions in this guide to enable Turbo Mode via the BIOS Setup Utility.
Power on the system and press [DEL] to enter the BIOS Setup Utility. Navigate to the [Advanced] tab and select [RC Advanced Menu].
Within the [RC Advanced Menu], select [Power & Performance].
In the [Power & Performance] menu, select [CPU Power Management Control].
4. Locate [Turbo mode] at the top of the menu. Select this item and press [ENTER] to change the value from [Disabled] to [Enabled]. No other settings need to be modified.
5. Press [F10] to save your changes and exit the BIOS Setup Utility. Turbo Mode is now enabled on your CL260.
The Security menu contains the following options:
Current TPM Device (read-only; possible values: Not Detected, TPM 1.2, TPM 2.0)
TPM Active PCR Hash Algorithm (read-only)
TPM Hardware Supported Hash Algorithm (read-only)
The Power menu contains the following options:
Wake on RTC from S5
Auto wake on S5, By Day of Month or Fixed time of every day
Restore AC Power Loss
The Boot menu contains the following options:
Network Stack
Network Stack Support: Windows 8 BitLocker Unlock, UEFI IPv4/IPv6 PXE, Legacy PXE OPROM
PXE Boot capability
The exit screen provides options to leave the setup utility and to load and save settings.
Exit Saving Changes: saves the current configuration and restarts the system to apply it
Save Change Without Exit: saves the current configuration but does not restart the system
Exit Discarding Changes: returns to the front page without saving or applying the current configuration
F5/F6 change the selected option to its previous or next value
Esc returns to the previous menu
F9 restores all options to their factory default values
F10 saves all options and restarts the system
RTC coin cell battery < 2.5V
Fast blinking
At BIOS boot-up
LAN WAKE
Enable/Disable LAN WAKE
USB Type-A S4/S5 keep power
Enabled to make USB A continue to supply power in S4/S5
Serial Port
Select RS485/RS422/RS232/Loopback function
Hardware Monitor
Display voltage information
Onlogic Feature Configuration
Onlogic features described in Section 2 above
RC Advanced Menu
Advanced settings on platform
Boot Configuration
Configure boot settings
Advanced Platform Information
Console Redirection Configuration
Console redirection allows the input and output of a computer's console to be rerouted to another device or location, often for remote management or troubleshooting.
TrEE Protocol Version (default value: 1.1; possible values: 1.0, 1.1)
TPM Availability (default value: Available; possible values: Available, Hidden) When Hidden, don’t exposes TPM to OS
TPM Operation - a command setting that tells the computer what to do with the security chip the next time it reboots.
UEFI PXE : IPv4/IPv6
Legacy : Legacy PXE OPROM only
Boot Device Type Order
Change boot device type order
Hard Disk Drive
Change hard drive boot order
Others
Changer other device boot order
Load Custom Defaults: loads a previously saved custom configuration
Save Custom Defaults: saves the current configuration so it can be loaded later
Discard Changes: restores the current configuration to its original state
Faulty condition
Error LED
When to detect
DIMM error
Constant on
At BIOS boot-up
No boot device found
Slow blinking








At BIOS boot-up
An ultra-compact, fanless edge gateway with dual LAN, dual Display over USB-C, and Intel® Quad-Core processing.
For more information on accessories and additional features, visit the CL260 product page:
Do not open and modify the device! The device complies with various national and international Safety, EMC and Environmental requirements per various standards.
Modification of the device may void certifications, warranty and/or cause possible injury to the user.
Safe use and installation instructions
Ne pas ouvrir et modifier l'appareil ! L'appareil est conforme à diverses exigences nationales et internationales en matière de sécurité, de CEM et d'environnement selon diverses normes.
La modification de l'appareil peut annuler les certifications, la garantie et/ou causer des blessures à l'utilisateur.
Instructions d'utilisation et d'installation en toute sécurité
If you purchased additional items such as mounting brackets, power supplies or terminal block connectors, they will be located in the system box or within the outer shipping carton.
For more information on accessories and additional features, visit the CL Series Product page.
CL260 Product Page:
The CL260 is pictured with 2 RP-SMA antenna plugs.
The front power button can be used to turn on and off the CL260 system. The power button is a momentary contact button without LED.
A single press while the system is on will initiate a graceful Shutdown or Sleep operation from the OS
Pressing and holding the button for 4 seconds while the system is running will cause a forced shutdown
The system can be woken by a single press of the power button from any state
USB 3.2 Gen 1 (5 Gbps)
DisplayPort 1.4 compliant in DisplayPort Alt Mode
Power output up to 5V/3A
USB 3.2 Gen 1 (5 Gbps)
The LAN Ports on CL260 supports up to 1Gbps link speeds over standard shielded CAT5e or CAT6 cables. The connector is the industry standard RJ45 connector. The LAN link state is shown by the two LEDs enclosed in the port. The description is included below.
When Factory Reset Button is pressed, it resets system BIOS settings back to factory defaults. In order for the factory reset button to be functional it must be enabled in the BIOS setup menu.
The mainboard power is applied to the CL260 platform through a 3-pin terminal block connector (Mating part: Dinkle / OnLogic 0225-0603 or equivalent).
The system is operational from 12V~24V. The maximum rated current of the connector is 15A per pin. Use a wire gauge that is rated for the operational current. Cables should be properly terminated with wire ferrules. Do not use the terminal block with tinned wire ends or solid core wire. See below for the connector pinout which is also indicated on the terminal block mounting panel adjacent to the connector. Installation of DC Mains connection shall only be performed by skilled personnel and in accordance with your local and national electrical code (Example: NEC, CEC).
When using the remote switch connections with the terminal block option, mating power switch cables should be a twisted-pair wire with floating shield to assure proper immunity to EMI/RFI. It is recommended to keep wires at less than 3 meters in length. Switches should be momentary contact type only.
USB 3.2 Gen 1 (5 Gbps)
DisplayPort 1.4 compliant in DisplayPort Alt Mode
Power output up to 5V/3A
Serial Port (10-Pin Terminal Block)
The serial ports support RS-232, RS-422, and RS-485 configurations. Refer to the for configuration instructions.
(Mating part: Dinkle 0159-0110 / OnLogic TB10P or equivalent).
The motherboard top and bottom view for CL260 is as below.
An M.2 E-Key port is present on the Helix motherboard to allow support for E-Key form-factor wireless expansion cards. Only 2230 form-factor cards are supported. The E-Key connector on the CL260 platform supports PCIe Gen 3 x1 and USB 2.0.
A full pinout table for this expansion slot is provided in Expansion Port Pinout
An M.2 M-Key port is present on the Helix motherboard to allow support for M-Key form-factor expansion cards. Only 2280 form-factor cards are supported. The M-Key connector on the CL260 platform includes support PCIe Gen 3 x2 and SATA III.
A full pinout table for this expansion slot is provided in Expansion Port Pinout
If the BIOS needs to be updated, please refer to the for reflashing instructions.
The RTC battery on the CL260 platform is used to maintain the real-time clock for the system. If the RTC battery is low, the Error LED will indicate the error event. The cabled RTC battery should be replaced with an UL listed battery. The battery shall use a ACES 50276-002H or equivelent connector to mate with the on-board connector.
Two Intel Twin Lake Processor options are available for the CL260.
The CL260 platform has the onboard LPDDR5 chips:
Capacity: 8GB
Speed: 4800 MT/s
The power consumption of the CL260 system was measured for various system configurations, workloads, and power states at 12V system input voltages. Tests were performed using BurnInTest v10.2 to stress system components. The build configurations and power consumption are listed in the tables below.
*The configurations below are using representative samples of internal devices, the specific components mentioned below may vary from the devices provided by OnLogic. The power consumption for each system configuration is record below
Configuration 1 : N150
Configuration 2 : N250
These DC levels specified are the absolute max values for the pins for function and safety of the system. The protection circuitry allows for brief transient voltages above these levels without the system turning off or being damaged. A transient voltage suppressor on the power input allows momentary excursions above stated limits. For input power consumption and current see Power Consumption
The CL platform supports multiple power states. The wake-up events can be configured in the BIOS. This section describes the supported power management functions and gives information on protection circuitry for power adapters. Low power shutdown is an additional option in the BIOS. See for more information.
Pressing Delete key while the system is booting, then navigate to Power -> Restore AC Power Loss Select Power On to enable auto power on Select Power Off to disable auto power on
Temperature Range: 0ºC to 50°C
Step size: 10°C
Place the system in a chamber with 0.7 m/s of airflow and run the Furmark stress test
Step 1: Align the two screw holes on the back of the system with the respective holes on the DIN Clip (MTD109).
Step 2: Attach DIN Clip (MTD109) to the system using the supplied M3 screws (M3X0.5 Flathead Screw, 6mm Long).
Step 3: Mount system onto the DIN rail.
Note: The mounting brackets are required to support 4x the hanging weight of the system. The mating surface and hardware must be capable of supporting the same load.
Step 1: Align the two screw holes on the back of the system with the respective holes on the VESA mounting bracket (MTW117).
Step 2: Attach VESA Mounting Bracket (MTW117) to the system using the supplied M3 screws (M3X0.5 Flathead Screw, 6mm Long)
Step 1: Peel feet from releasing paper.
Step 2: Adhere feet on the bottom side or CL260.
Properly opening OnLogic systems does not void the warranty in most cases, however, some precautions are necessary to avoid damaging the system.
Perform this disassembly in an area free of static discharge.
Disconnect power, video, and any other connections to the system. It should be fully unplugged.
Ideally, wear a grounding strap. If that is not available, regularly touch a grounded metal surface to discharge your body of static electricity.
Windows 11 Drivers -
(Follow our guide for )
For the full BIOS manual, please .
*Update the BIOS with the file(s) above. You can follow this guide for installation instructions. PLEASE NOTE - this is a SIGNED BIOS.
The BIOS controls the serial port configurations. Go to the following BIOS settings to adjust the communication types. Access the BIOS by pressing <DEL> at boot up.
Set the communication type, navigate to:
Advanced –> Serial Port
RS232 (default)
RS422
RS485
Make sure to save any changes by pressing F10 to Save and Exit.
The CL260 features a factory reset button to manually restore the BIOS to its default settings.
Locate the factory reset button on the front plate.
Press the reset button to restore system BIOS settings back to factory defaults or custom set values.
120-ohm termination resistor:
For RS-422 and RS-485, the internal 120Ω termination resistor is enabled by default.
RS-485 Built-in biasing/fail-safe:
The transceiver supports enhanced fail-safe operation and does not require external biasing resistors to maintain a defined receiver state when the bus is idle.
Standard RS-485 biasing:
The transceiver implements an enhanced fail-safe receiver function. When the bus is open, shorted, or idle (un-driven), the receiver output is guaranteed to remain at a logic-high state. Therefore, no external RS-485 biasing resistors are required.
This device has been tested to the relevant EMC and Safety standards. Modifications by the user may invalidate certifications. Testing included EN 55032, EN 55035, EN 60601-1-2, EN 62368-1, EN 18031-1 (RED 3.3d) and IEC 60945 Ed. 4.
This device complies with part 15 of the FCC rules as a Class A device. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
The computer system was evaluated for medical, IT equipment, automotive, maritime and railway EMC standards as a class A device. The computer complies with the relevant IT equipment directives for the UKCA mark.
For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.
LAN Controller
2x Realtek RTL8111H-CG (1 GbE)
Expansion
1x M.2 2280 M-Key (PCIe Gen3 x2, SATA III)
1x M.2 2230 E-Key (PCIe Gen3 x1, USB 2.0)
Right I/O
1x USB 3.2 Gen 1 Type-C (DP 1.4, 5V/3A)
1x Serial Port (RS-232/422/485)
1x 3-pin Terminal Block with 12~24 V Input
Front I/O
1x USB 3.2 Gen1 Type-C (DP 1.4, 5V/3A)
4x USB 3.2 Gen1 Type-A
2x 1 GbE LAN
1x Reset Button 1x Power Button
Onboard Headers & Connectors
1x Battery on a cable
Voltage Input
12V - 24V
Power Input
3-Pin Terminal Block
Operating Systems
Windows 11 IoT Enterprise LTSC 2024
Windows 11 Professional
Ubuntu 24.04 - Desktop Ubuntu 24.04 - Server
Special Features
Watchdog Timer TPM 2.0 onboard IC
Thermal Standards
Operating Temperature: 0-50℃
Storage Temperature: -20-85℃
Operating Humidity: 5% - 95% (non-condensing) * When using an approved AC adapter the Operating Temperature is 0-40℃.
Extra Chassis Features
2 Antenna holes
DIN Rail Mount VESA Mount
Regulatory
SAFETY Listings + CB ( Intertek File 5019151)
IEC/UL/EN 62368-1, 61010-1, 61010-2-201
EMC CISPR 32/35 Class A
FCC Part 15 Class A
IEC/EN 60601-1-2:2014 Medical Immunity
Radio Equipment Directive (2014/53/EU) [Only applicable for configurations with wireless transmitters and includes LTE/Wifi/BT together]
RoHS 3 Directive (2015/863/EU)
WEEE Directive (2012/19/EU)
LAN
2x 1GbE connected
2x 1GbE connected
Storage
Transcend 256GB TS256GMTS970TI-VS1
Transcend 256GB TS256GMTS970TI-VS1
M.2 E-Key
Intel AX210NGW
Intel AX210NGW
COM
Loopback plug connected
Loopback plug
OS
Windows 11 IoT LTSC 2024
Windows 11 IoT LTSC 2024
S3 (WoL enabled)
0.651
Windows S0 Idle
8.698
CPU Stress Only (Burn-In)
12.876
All Components Stress
13.306
All Components Stress (Burn-In)
w/ USB max loaded (2x USBC + 2x USBA)
60.220
S3 (WoL enabled)
0.712
Windows S0 Idle
11.386
CPU Stress Only (Burn-In)
14.310
All Components Stress (Burn-In)
14.676
All Components Stress (Burn-In)
w/ USB max loaded (2x USBC + 2x USBA)
62.448
USB
S4 S3
RTC Wake Set by BIOS
S5
RTC Wake Set by OS
S3
Read the entire manual before using the product.
Install the device securely per users manual instructions.
Wall or ceiling mounting device requires use of OnLogic mounting plate or bracket.
Use M3x0.5mm Flat Head screws to attach mounting plate or mounting brackets to threaded holes on bottom or rear of chassis. Screws should be a minimum length of 4mm. Add 1mm of screw length for every mm of additional thickness of plate or bracket beyond 1.5mm.
Caution, Hot Surface! It is normal for the unit to heat up and be hot to touch. Do not touch the heatsink area or enclosure during operation and 30 minutes after shutdown allowing the unit to cool down.
Ambient operating temperature must be between 0 °C to 50 °C with a non-condensing relative humidity of 10-85%.
The device can be stored at temperatures between -10 °C to 85 °C. Note: Unit must be stabilized within operating temperature before use, minimum 3HR.
Keep the device away from liquids and flammable materials. Not to be installed in a hazardous environment.
Do not clean the device with liquids. The chassis can be cleaned with a dry cloth or duster only. To prevent injury to self and/or damage to the device the unit must be powered down and all connecting power and other peripherals shall be disconnected prior to cleaning.
Allow adequate space around all sides of the device for proper cooling and to not exceed its maximum operating temperature limit. If the device is mounted to a vertical surface then recommended device orientation is such that heatsink fins allow air to rise unobstructed. Alternative orientations may result in reduced operational temperature range.
This device is intended for indoor operation only.
Caution, Risk of Electric Shock! Unit is powered by low voltage DC (Direct Current) only! Do not connect AC (Alternating Current) into the device!
To power the device use only UL Listed external power supplies with DC output of 12-24VDC, see specs for details.
Install the device only with shielded network cables.
The installer should be experienced in aftermarket installation and familiar with general practices for installing electronics.
This equipment is intended to be used in Restrict Access Location. The Restrict Access Location must only be accessed by a Skilled person or by Instructed person.
Service and repair of the device must be done by qualified skilled service personnel. This includes, but is not limited to, replacement of the CMOS battery. Replacement CMOS battery must be UL recognized and of a similar type as the original.
Proper disposal of the CMOS battery must comply with local governance.
Radio device is not intended for emergency service use.
To protect against excessive RF exposure, maintain at least 20cm from any user and the RF antennas. Only use provided dual band PIFA antennas with 2dBi/2dBi gain (2.4 and 5Ghz) for Wifi/BT.
This equipment is not suitable for use in locations where children are likely to be present.
WARNING: There is danger of explosion if the CMOS battery is replaced incorrectly. Disposal of battery into fire or a hot oven, or mechanically crushing or cutting of a battery can result in an explosion.
Lisez l'intégralité du manuel avant d'utiliser le produit.
Installez l'appareil en toute sécurité selon les instructions du manuel de l'utilisateur.
Pour vous protéger contre une exposition RF excessive, maintenez au moins 20 cm de tout utilisateur et des antennes RF. Utilisez uniquement les antennes double bande fournies avec un gain de 2 dBi/2 dBi.
Le dispositif de montage mural ou au plafond nécessite l'utilisation d'une plaque ou d'un support de montage. La plaque ou le support doit être en métal et avoir une épaisseur minimale de 1 mm.
Utilisez des vis à tête plate M4x0,5 mm pour fixer la plaque de montage ou les supports de montage aux trous filetés au bas ou à l'arrière du châssis. Les vis doivent avoir une longueur minimale de 4 mm. Ajoutez 1 mm de longueur de vis pour chaque mm d'épaisseur supplémentaire de plaque ou de support au-delà de 1,5 mm.
Attention surface chaude! Il est normal que l'appareil chauffe et soit chaud au toucher. Ne touchez pas la zone du dissipateur thermique ou le boîtier pendant le fonctionnement et 30 minutes après l'arrêt pour permettre à l'unité de refroidir.
La température ambiante de fonctionnement doit être comprise entre 0 °C et 40 °C avec une humidité relative sans condensation de 10 à 85 %.
L'appareil peut être stocké à des températures comprises entre -10 °C et 85 °C. Remarque : L'unité doit être stabilisée à la température de fonctionnement avant utilisation, minimum 3 heures.
Gardez l'appareil à l'écart des liquides et des matériaux inflammables. Ne pas installer dans un environnement dangereux.
Ne nettoyez pas l'appareil avec des liquides. Le châssis peut être nettoyé uniquement avec un chiffon sec ou un plumeau. Pour éviter de se blesser et/ou d'endommager l'appareil, l'appareil doit être éteint et toutes les alimentations et autres périphériques doivent être déconnectés avant le nettoyage.
Prévoyez un espace suffisant autour de tous les côtés de l'appareil pour un refroidissement correct et pour ne pas dépasser sa limite de température de fonctionnement maximale. Si l'appareil est monté sur une surface verticale, l'orientation recommandée de l'appareil est telle que les ailettes du dissipateur thermique permettent à l'air de monter sans obstruction. Des orientations alternatives peuvent entraîner une plage de températures de fonctionnement réduite.
Cet appareil est destiné à une utilisation en intérieur uniquement.
Attention, risque de choc électrique ! L'unité est alimentée uniquement par une basse tension CC (courant continu) ! Ne connectez pas le courant alternatif (courant alternatif) à l'appareil !
Pour alimenter l'appareil, utilisez uniquement des alimentations externes répertoriées UL avec une sortie CC de 12-24 VCC, voir les spécifications pour plus de détails.
Les méthodes de câblage utilisées pour le raccordement de l'équipement à l'alimentation secteur doivent être conformes au Code national de l'électricité, NFPA 70, et au Code canadien de l'électricité, Partie I, CSA C22.1.
Prévoyez suffisamment d'espace pour les connexions de câblage du bornier afin que les fils ne se plient pas et soient protégés contre les dommages accidentels.
Installez l'appareil uniquement avec des câbles réseau blindés.
L'installateur doit avoir de l'expérience dans l'installation de pièces de rechange et être familiarisé avec les pratiques générales d'installation de composants électroniques.
Cet équipement est destiné à être utilisé dans un lieu à accès restreint. L'accès à ce lieu est réservé à une personne qualifiée ou formée.
L'appareil radio n'est pas destiné aux services d'urgence.
L'entretien et la réparation de l'appareil doivent être effectués par un personnel qualifié. Cela inclut, mais sans s'y limiter, le remplacement de la batterie CMOS. La batterie CMOS de remplacement doit être du même type que celle d'origine.
L'élimination appropriée de la batterie CMOS doit être conforme à la gouvernance locale.
Le produit doit uniquement être connecté à un routeur, un commutateur ou un équipement réseau similaire certifié
Le produit est destiné à une utilisation en intérieur uniquement.
Le produit ne peut pas être connecté au réseau public.
Cet équipement n'est pas adapté à une utilisation dans des endroits où des enfants sont susceptibles d'être présents.
ATTENTION: Il existe un risque d'explosion si la pile CMOS n'est pas remplacée correctement. L'élimination de la batterie dans le feu ou dans un four chaud, ou l'écrasement ou le découpage mécanique d'une batterie peut entraîner une explosion.
System Dimensions
4.5" x 1.2" x 3.2", 115x 30 x 82 mm
CPU (on solder side of board)
Intel® N150, N250
Memory
LPDDR5 8GB
The Power LED indicates the system events:
Powered on in the S0 State: Constant on
System is in the Sleep State (S3): Flashing
System is in S5 or deeper state: Off
Read/Write activities on M.2 storage device: Blinking
The Error LED indicates the system error events:
DRAM Error: Constant on
No boot device found: Slow blinking (0.5 Hz)
Low Battery: Fast blinking (4 Hz)
1
DC +
2
Earth GND
3
DC -
N150
CL260-N150-P
8GB / 4 / 4
N250
CL260-N250-P
CPU
N150
N250
Memory
LPDDR5 8GB
S5 (WoL disabled)
0.614
S5 (WoL enabled)
0.626
S3 (WoL disabled)
0.626
S5 (WoL disabled)
0.675
S5 (WoL enabled)
0.688
S3 (WoL disabled)
0.675
Nominal Operating Voltage (Rated DC value of input)
12V - 24V (± 15%)
Rated Power Consumption
65W
Power Button
Pseudo G3 S5 S4 S3
LAN
S5 S4 S3
1.05E
Production Version
For both USB-C Ports the Power Output is as follows: At 45℃ Ambient Temperature power output is 5V/3A
At 50℃ Ambient Temperature power output is: 5V/0.9A
For the best and safest results, please use the UL approved and tested power supply. Using an alternative power supply may pose a safety risk. If you need further assistance, please contact an OnLogic Sales Representative for more information.
Wire Type: Cu. Only use 28 to 16 AWG wire size (Maximum Temperature Rating: 130°C)
One of the Type-C ports is for connecting to an external monitor. This machine is intended for standalone use and not to connect with multiple machines.
It is recommended that this is to be performed by skilled personnel.

























8GB / 4 / 4
LPDDR5 8GB