Access the official Motherboard Manual & OEM Resources from ASRock. This external link provides access to the complete motherboard manual, along with the latest BIOS updates and specific drivers for your system's motherboard (SBC-330M)
Internal Access
The ML340 can be opened by the user. This does not void the warranty, however, any damage caused by doing so will not be covered.
1. Ensure your body is discharged of any static electricity by touching a grounded metal surface.
2. Begin by removing the 3x Phillips case screws on the back and the 2x Phillips screws from the bottom, circled in red below:
3. Use the tab for leverage to pull the bottom panel off as shown below:
4. You now have complete access to the internals.
Locate the AT/ATX jumper.
Move it over by 1 pin, closer to the edge of the board.
Auto power on is now enabled.
Locate the CLRMOS1 jumper.
Move the jumper over by 1 pin.
Wait 30 seconds.
Restore the jumper to its original position. The CMOS is now clear.
Ensure your body is discharged of any static electricity by touching a grounded metal surface.
Begin by removing the 3x Phillips case screws on the back and the 2x Phillips screws from the bottom, circled in red below:
Use the tab for leverage to pull the bottom panel off as shown
Using needle nose pliers or similar, push out the knockouts for the WiFi antenna cables.
Insert the antenna cables into the knockouts from the inside of the case. Apply the washer and nut to the outside. Tighten down.
Insert the WiFi card into the mini-PCIe slot at a 45 degree angle.
Push down and install m2 screw to secure card
Attach the antenna cables to the WiFi card. OnLogic standard is to connect the leftmost antenna cable to Main, the and the rightmost to AUX – with the rear of the system facing you right side up.
For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.
Power on the ML350 and press the Esc key a few times to access the BIOS
Navigate to the Chipset tab
Change auto power on to [enable]
The ML350 can be opened by the user. This does not void the warranty, however, any damage caused by doing so will not be covered. Here are the steps to opening your ML350:
Ensure your body is discharged of any static electricity by touching a grounded metal surface.
Remove the two silver Phillips screws from the bottom of the unit as circled in red below:
Remove the bottom 3 Phillips screws from the back plate (blue arrows shown below).
Using your fingernail or a Flathead screwdriver, pry the bottom plate off using the provided leverage tab (yellow arrow shown below).
Locate the Clear CMOS jumper as shown below:
Remove the jumper from pins 2 and 3.
Install it onto pins 1 and 2, moving it over by 1 pin.
Wait 30 seconds.
Restore the jumper to its original 2-3 position. The CMOS is now clear.
Re-install the bottom plate and all 5 screws.
Note: The unit may power cycle several times before it boots up. This is normal.
Unpack the VESA mounting plate and remove the bubble wrap.
Be sure not to throw away the screw bag inside.
You should have everything pictured here.
Use the smaller of the included screws to attach the mounting plate to the bottom of your system.
Locate the VESA screw holes on the back of your monitor or mounting arm.
Install the 4 bolts hand tight.
Hang the system on the back of the display by lining up the bolts with the holes.
Push the bolt head through the center of the + cutouts and slide the system down to lock in place.
Mounting plate shown without PC for illustration purposes
Make sure the PC slides downward and all 4 bolts are engaged.
For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information.
Save & Exit
The ML350 will now automatically turn on when power is connected