HX310 / HX330
Intel Celeron/Pentium Industrial Edge Computer. This page also applies to the TM260 ThinManager Ready platform.
1- Product Overview
1.1- Introduction
The Helix 300 Series harnesses the enhanced power and capabilities of Intel "Elkhart Lake" Celeron and Pentium processors in a low profile fanless system built for the challenges of the IoT edge. With support for triple independent 4K displays, a 0°C to 50°C operating temperature range, and a wealth of configuration options, the Helix 310 and Helix 330 were engineered with versatility in mind. The systems also feature compliance testing for IT Equipment EMC and Safety and pre-compliance testing for IEC 60601-1-2 (4th edition) medical immunity.

1.2- Safety
1.3- Box Contents & Accessories
4x Rubber Feet
Power cable retention clip
If you purchased additional items such as mounting brackets, power supplies or terminal block connectors, they will be located in the system box or within the outer shipping carton. All drivers and product guides can be found on the corresponding product page. For more information on accessories and additional features, visit the Helix Product pages.
1.4- Product Specifications


Radio Specifications when equipped with INT-9260 Wifi/BT (device for indoor use)


*Note: Limited RS422/485 capability. See Appendix H for details.
2- Technical Specifications
2.1- External Features
Front I/O




Rear I/O

2.2- I/O Definitions
Front I/O Definition
Power Button / Power LED
The front power button can be used to turn on and off the Helix system. The power button is a momentary contact button with a blue LED backlight used to display the status of the system. A single press while the system is on will initiate a graceful shutdown operation from the OS. Pressing and holding the button for 4 seconds while the system is running will cause a hard reset of the system. The system can be woken by a single press of the power button from any state. The LED backlight will indicate the system status. A solid blue light indicates that the system is powered in the S0 state. A flashing blue light indicates the system is in the sleep state. The LED is off in S5 and deep sleep states.
SIM Card
A 3FF Subscriber Identity Module (SIM) card slot is present on the front panel of the Helix platform allowing native support for OnLogic cellular modules. The SIM signals are connected to the M.2 B-Key internal expansion slot. In order to access the SIM Slot, the Modbay panel and bottom plate must first be removed. The Modbay panel is secured by two screws on either side, pictured above in the “Front I/O Definition” section. The SIM slot is a Push-Push type receptacle. To insert or remove the SIM card from the front panel of the Helix platform, please use a small implement to push the card into the slot until it clicks. To remove the card, push with a small implement until the card clicks, then pull on the free end of the card to remove it.
COM DB9 Option The serial port mode on Helix can be selected in the BIOS configuration. The serial ports support RS-232, RS-422, and RS-85 configurations. Refer to the BIOS manual for configuration instructions.
COM DB9 Option
The serial port mode on Helix can be selected in the BIOS configuration. The serial ports support RS-232, RS-422, and RS-85 configurations. Refer to the BIOS manual for configuration instructions.

CAN DB9 Option
The CAN port on Helix supports CAN2.0 A/B at baud rates from 100-100 kbaud. The system CAN port is not internally terminated, and a properly terminated (120 Ohms, typical) cable should be used. CAN messages may be sent and received through the sideband Programmable Services Engine, via the Host Embedded Controller Interface (HECI). Windows drivers are available for this interface, and a command line tool is available for download.

USB 3.2
There is one USB 3.2 Gen 2 port on the front panel of the Helix platform. This port is capable of linking at 10Gb/s transfer rates.
USB 2.0
There is one USB 2.0 port on the front panel of the Helix platform. This port is capable of linking at 480 Mb/s transfer rates.
DIO Option
The Helix platform supports an optional Isolated Digital I/O add-in card through a 10-pin terminal block (Mating connector: Phoenix Contact pn: #1840447 or similar). This option allows for integration of the Helix platform with existing PLC integrations or other digital logic applications. The Digital IO may be managed through the sideband Programmable Services Engine, via the Host Embedded Controller Interface (HECI). Windows drivers are available for this interface, and a command line tool is available for download from our support website. For a complete explanation of features, operating voltages, and safety information, please refer to the DIO expansion manual on the OnLogic support site.

GND
In 4
In 3
In 2
In 1
Out 4
Out 3
Out 2
Out 1
Power
Dual LAN Option (HX330)
The HX330 supports up to two additional LAN ports on the front Modbay slot of the system. Both ports are Intel I210 network controllers.
Rear I/O Definition
Barrel Jack Power Connector
Mainboard power is applied to the Helix platform by way of a female barrel jack connector (OD: 5.5mm ID: 2.5mm. 12mm length ). The system is operational from 9V~24V at 5 amps, 12V only operation is at 3A. The maximum rated current of the connector is 7A. Use a wire gauge that is rated for the operational current.

DisplayPort 1, 2, &3
Helix utilizes Intel’s Integrated Gen 11 processor graphics that power the onboard DisplayPorts. This means resolutions up to 4096x2160 @ 60Hz are supported on all three outputs simultaneously. All ports support Multi-Stream Transport (MST).
LAN1 - MaxLinear GPY115 PHY
Helix supports up to 1Gbps link speeds over standard shielded CAT5e or CAT6 cables. This is done using the Integrated MAC and the MaxLinear GPY115 PHY. The connector is the industry standard RJ45 connector. The LAN link state and activity is shown by the two LEDs enclosed in the port. The description is included below.
LAN2 - MaxLinear GPY115 PHY
The second LAN Port on Helix supports up to 1Gbps link speeds over standard shielded CAT5e or CAT6 cables. The connector is the industry standard RJ45 connector. The LAN link state and activity is shown by the two LEDs enclosed in the port. The description is included below. The second LAN port is available only with the Pentium J6426 CPU option.

USB 3.2
The dual stack USB 3.2 ports on the rear panel are USB 3.2 Gen 2 ports, capable of linking at 10Gb/s transfer rates.
Terminal block power option
If the terminal block power option is selected, mainboard power is applied to the Helix platform through a 4-pin terminal block connector (Mating part: Phoenix Contact #1840382 or equivalent).
The system is operational from 9V~24V at 5 amps, 12V operation is at 3A. The maximum rated current of the connector is 6A per pin. Use a wire gauge that is rated for the operational current. Cables should be properly terminated with wire ferrules. Do not use the terminal block with tinned wire ends or solid core wire. Always follow the part number tightening torque and wire sizing specifications to prevent damage to connector systems and PC. See below for connector pinout.
When using the remote switch connections with the terminal block option, mating power switch cables should be a twisted-pair wire with floating shield to assure proper immunity to EMI/RFI. It is recommended to keep wires at less than 3 meters in length. Switches should be momentary contact type only.

Expansion Port Pinout
M.2 B-Key

M.2 E-Key

M.2 M-Key

2.3- Motherboard Connectors
The motherboard is the same for HX310 and HX330. The second LAN port is only available for configurations with the Pentium J6426 CPU option.


M.2 B-Key
An M.2 B-Key port is present on the Helix motherboard to allow support for B-Key form-factor expansion cards. Supported cards include 3042, 2242, 2260, 2280 form-factors. The B-Key connector on the Helix platform supports PCIe Gen 3 x1, USB 3.2 5Gb/s, USB 2.0, SATA Gen I (1.5Gbps), SATA Gen II (3.0Gbps), and SATA Gen III (6.0Gbps) devices.
The 3FF Micro SIM card slot is available for OnLogic 4G Extrovert modules.
M.2 E-Key
An M.2 E-Key port is present on the Helix motherboard to allow support for E-Key form-factor wireless expansion cards. Only 2230 form-factor cards are supported. The E-Key connector on the Helix platform supports PCIe Gen 3 x1 and USB 2.0.
M.2 M-Key
An M.2 M-Key port is present on the Helix motherboard to allow support for M-Key form-factor expansion cards. Only 2280 form-factor cards are supported. The M-Key connector on the Helix platform includes support for PCIe Gen 3 x2, SATA Gen I (1.5Gbps), SATA Gen II (3.0Gbps), and SATA Gen III (6.0Gbps) devices.
SO-DIMM1 & SO-DIMM2
The Helix platform has two onboard DDR4 SO-DIMM Slots. Below find the specifications of the two SO-DIMM Slots:
Maximum Capacity: DDR4-3200 32GB with two 16GB SO-DIMM Modules
Channel configuration: 1DIMM Per Channel (DPC) - 2 Channels
No ECC Support
COM1 & COM2
The two on-board COM headers utilize standard 9-pin 2.54mm pitch male pin headers with the pin configuration in the chart below. These serial ports support RS-232, RS-422 Full-Duplex, and RS-485 half-Duplex configurations. The serial port communication mode can be selected in the BIOS configuration. Refer to the BIOS manual (Appendix C) for configuration instructions.
CAN
The on-board CAN transceiver headers utilize standard 9-pin 2.54mm pitch male pin headers with the pin configuration in the chart below. Refer to the CAN user guide for configuration instructions.
Power Switch Header
The on-board power switch header can be used to control the power state of the Helix platform in parallel with the front panel power button. Mating power switch cables should be a twisted-pair wire with floating shield to assure proper immunity to EMI/RFI. Mating connector is a standard 2.54mm female header. It is recommended to keep wires at less than 3 meters in length. Switches must be momentary contact type only.
ATX/CMOS Jumper Header
A 2mm pin header and jumpers are used to clear the CMOS settings and select the hardware auto power-on behavior of the Helix platform.
ATX mode can be selected by moving the pin jumper to connect pins 3 and 5 will select ATX power mode. The system power-on will be controlled by the system power button or other supported wake events. When the pin jumper is moved to connect pins 1 and 3, the system will operate in AT mode, where the system will power on when system power is first applied. The default selection is ATX mode.
The system CMOS settings can be cleared with the second pin jumper. To clear the CMOS the following steps shall be followed:
Disconnect system power.
Place jumper in the “clear” position.
Wait 10 seconds.
Remove jumper from the “clear” position and return to default position
RTC Battery Header
The RTC battery on the Helix platform is used to retain BIOS CMOS settings and maintain the real-time clock for the system. If the RTC battery is low, CMOS settings will not be retained and you may receive an alert in the operating system. The cabled RTC battery should be replaced with a Maxell CR2032-WK11 (or UL listed equivalent). An equivalent battery shall use a Hirose DF13-2S-1.25c connector to mate with the on-board connector.
TPM Header
Helix features an onboard TPM (Trusted Platform Module) header. Helix supports OnLogic’s module (OnLogic part TPM01) featuring TPM 2.0. This gives the option to have a dedicated secure module to secure Helix through cryptographic keys.
Fan Header
The on-board fan header can power and control any five volt three or four-wire fan (including variable-speed PWM fans) using the standard pin configuration in the chart below. Three-wire fans will only connect to pins 1-3. This header utilizes a standard 4-pin 2.54mm pitch fan connector with a small retention tab. Any mating connector with the standard form factor, such as Molex part number 0470541000, can be used to connect a fan. Most CPU and case fans utilize this connector and pinout. The 5V pin on this connector can provide up to 1A of current.
USB 2.0 Header
The on-board USB 2.0 header provides a single USB 2.0 signal. It utilizes a standard 4-pin 2.54mm pitch male pin connector with the pin configuration in the chart below. The 5V power pin (Pin 1) can provide up to 1A of current.
Power Input Header
Mainboard power can be applied to the Helix platform by way of the 4-pin JST XH-4 connector (Mating part: JST XHP-4 or equivalent). The system is operational from 8V~24V. The maximum rated current of the connector is 3A per pin. Use a wire gauge that is rated for the operational current. See below for connector pinout.
Supplemental 5V Power Output
Additional 5V power can be supplied (to internal devices only) by use of the 2-pin header on the motherboard. The maximum rated current of the connector is 2A per pin. Use a wire gauge that is rated for the operational current. See below for connector pinout.
2.4- Processor
Two CPU options are available for both the HX310 and HX330 models:
Celeron N6211: 2-core processor.
Pentium J6426: 4-core processor.
The second onboard LAN port is standard on configurations with the Pentium J6426 processor.
2.5- Power Management
Average Power Consumption
The power consumption of the HX310 system was measured for various system configurations, workloads, and power states at both 12V and 24V system input voltages. Tests were performed using Burnintest v9.0 build 1012 to stress system components with and without graphics enabled. The build configurations and power consumption are listed in the tables below.
*The configurations below are using representative samples of internal devices, the specific components mentioned below may vary from the devices provided by OnLogic. The power consumption for each system configuration is record below.
Protection Circuitry
These DC levels specified are the absolute max values for the pins for function and safety of the system. The protection circuitry allows for brief transient voltages above these levels without the system turning off or being damaged. A transient voltage suppressor on the power input allows momentary excursions above stated limits.
Wake-Up Events
The Helix platform supports multiple power states. The wake-up events can be configured in the BIOS. This section describes the supported power management functions and gives information on protection circuitry for power adapters. Low power shutdown is an additional option in the BIOS.
Auto Power On
The system can be configured to turn on automatically when DC power is connected. This is useful for power outage recovery or if the unit is mounted in a hard to reach location. You can enable Auto Power On by following the steps listed below.
Follow the Internal Access instructions.
Locate the jumper shown in purple

The bottom jumper in the below image (closest to the outside of the system) controls auto power on. It is called the AT/ATX jumper.

Use needlenose pliers or your fingernails to grab the jumper and remove it from the pins.

Reinstall the jumper as shown, Auto power on is now enabled (AT Mode)

2.6- Add-in Modules
Isolated DIO: Additional information for the Isolated DIO can be found here.
CAN Bus: An optional CAN DB9 port is available, supporting CAN2.0 A/B.
Cellular: OnLogic 4G modules are supported via the M.2 B-Key slot and the front-panel SIM slot.
Dual LAN: The HX330 supports two additional Intel I210 LAN ports in the front Modbay.
2.7- Thermal Results
The thermal performance of the Helix platform was validated by fully loading system components while the test system was exposed to the limits of its rated environment (0C-50C). CPU clock speeds and core temperatures were measured for the duration of the test. The results were analyzed by comparing the average clock speed over the duration of the test to the rated base clock speed. A passing result was defined by an average clock speed no less than 20% of the rated base clock and operation below the CPU Max temperature limit.
HX300 -Elkhart Lake SKU 3 1800mhz base clock 50C-0C Thermal Testing Graph - The image below shows the thermal test results from an HX300 in a thermal chamber over the course of 20 hours at a workload of 100%. After 17 Hours the 50C thermal chamber was brought down to 0C.
50°C Ambient Performance
CPU Temp.
<100°C
95°C
5°C
Restarted
<1 times
0 Times
100%
Avg. CPU Freq.
>1400 MHz
1648 MHz
+9%
0°C Ambient Performance
CPU Temp.
<100°C
49.9°C
50.1°C
Restarted
<1 times
0 Times
100%
Avg. CPU Freq.
>1400 MHz
1596 MHz
+11.1%



2.8- Block Diagram

3- Installation & Mechanical
3.1- Dimensions
Helix 300 Dimensions (HX310/HX330)

3.2- Mounting
Wall Mount & DIN Rail Mounting

Step 1: Attach wall mounting brackets MTW101 (no DIN), MTW101-K (DIN), MTW107 (Vertical DIN), VMPL-1041 (VESA) to the chassis using the supplied screws. Specifications can be found below:
Screw type: M3X0.5 FH 120 Degree Screw
Length: 4 mm
Step 2: Locate the 4 holes that line up accordingly to the bracket as shown below.
Step 3: Fasten system to surface. The mounting bracket systems are required to secure 3x the hanging weight of the computer system. The mating substrate must be capable of maintaining the same rating.
Step 4 (for DIN Bracket): Using the outer 2 holes of the 3 hole set on the wall mount bracket, line up the DIN bracket.
Step 5 (for DIN Bracket): Using the supplied screws, using a Phillips head screwdriver, mount the DIN bracket to the bracket.
Step 6 (for DIN Bracket): Mount system onto the DIN rail.



VESA Mounting
Step 1: Attach wall mounting brackets to the chassis using:
Screw type: M3X0.5 FH 120 Degree Screw
Length: 4 mm
Step 2: Locate the 4 holes that line up accordingly to the bracket as shown
Step 3: Fasten system to surface. The mounting bracket systems are required to secure 3x the hanging weight of the computer system. The mating substrate must be capable of maintaining the same rating.

3.3- Internal Access
Opening the system does not void the warranty, however, some precautions are necessary to avoid damaging the unit. Any damaged caused will not be covered by warranty.
Perform this disassembly in an area free of static discharge
Before beginning, touch a grounded metal surface to discharge your body of static electricity


4- Software & Firmware
4.1- BIOS
BIOS manual
For the full BIOS manual, please click here.
Update the BIOS with the file(s) below. You can follow this how-to guide for installation instructions.
4.2- Drivers & Downloads
BIOS Updates
Drivers
Hardware Control Application (HWC)
v1.2.1
10/11/2023
Download HWC Program must run as administrator in CMD
Fixes issue with Version-Check warning. * Note that the CAN baudrate is fixed at 1M. Please see our C-Based PSE-Examples for setting the baudrate programmatically.
Make sure your system’s drivers are installed and up-to-date.
Linux Support
This model uses the new Intel GPY115/EC1000S Ethernet controller provided by the Elkhart Lake platform. Some operating systems are not compatible, or require additional setup by the user for this Ethernet controller. *For systems purchased before March 1st 2023, Ubuntu can be installed after the Ethernet firmware has been updated. Customers interested in this can contact OnLogic Tech Support to RMA the system for this update.
4.3- Features & Configuration
Digital IO & CAN
The Helix 300 and 310 systems offer optional CAN bus and isolated Digital IO support. This functionality is through the processor’s supporting ARM microcontroller, known as the Programmable Services Engine (PSE).
The PSE is isolated from the core processor, runs its own OS (Zephyr RTOS), but can be sent messages over the system’s Host Embedded Controller Interface (or HECI). The OS is transparent to the user. This interface may be used to send and receive CAN messages alongside setting and reading the Digital IO.
Quickstart
Requirements: An HX300 or HX310 with Windows and the latest HECI driver. The HECI Windows driver is provided and supported by Intel, and will be preinstalled on HX300 units purchased with Windows. If Windows is installed by the user, the driver is included with our driver package linked at the top of this page.
Download the HX300’s Hardware Control Application (HWC).
Open a command window, and navigate to the location of the downloaded file.
Press the Windows Key + R
Type
cmd.exe
and hitEnter
In the window that opens navigate to the download location:
e.g.
cd C:\User\Username\Downloads
Display the built-in help text:
hwc.exe --help
DIO Examples
The (optional) MOD110 digital input/output (DIO) expansion adds up to eight digital inputs and outputs to the system, and an additional CAN port. It also optionally provides support for pulse width modulation (PWM) on three of the eight digital output pins, and support for using a quadrature encoder peripheral (QEP) in place of the first and/or second group of three digital inputs.
See our dedicated DIO article on how to get started with the MOD110 expansion module. The HX300 series utilizes the MOD106 DIO, however the PSE controls are the same for both parts and both are opto-isolated modules so this guide can be used for both.
Application Integration
The HECI interface uses packed structures to send data between the host and PSE. Specific type structures are provided in the sample code, but an outline of the message format is available below:
Bits
Description
0 – 7
HECI Command Identifier: 0x01: System Information: 0x02: Digital IO 0x04: Can Bus
8
Set as ‘1’ if this message is a response from the PSE
9
Set as ‘1’ if this message contains a valid data body
10 – 25
Packed ‘argument’ for a given command. Format depends on the command identifier.
26 – 31
Status of last command
32 – 39
Data format of body: 0: Raw data 1: Version information 2: CAN message 4: DIO message 7: ASCII String
40 – 168
Body of message data, usually in the form of another packed structure.
Input Impedance
Each digital input has a 10K internal pullup and a 10K series resistor.
TM260 ThinManager Firmware
The TM260 (the HX330 with ThinManager Ready firmware) is compatible with ThinManager 11 or higher. Customers interested in the ThinManager WiFi Boot option should use ThinManager 13.2 to enable this feature. Checkout our OnLogic Blog with more info about ThinManager WiFi Boot.
The TM260 requires version 14 of the Terminal Capability Database (TermCap) in order to properly download the firmware it needs to function. Customers can follow this Installation Guide to perform this update for their systems.
Using the TPM 2.0 Module
As with other newer model systems, this model includes a firmware TPM by default. It functions similarly to a TPM 2.0 module. If the optional dedicated TPM 2.0 module is added to the system, the firmware TPM will need to be disabled to allow it to function.
The firmware TPM can be disabled in the BIOS:
Power on the system and press Del to enter the Front Page menu.
Select Setup Utility.
Navigate to the Advanced tab and open Chipset Configuration.
Disable Platform Trust Technology.
Press F10 to save and exit.
The dedicated TPM should now be functional and detectable in TPM.MSC or Device Manager.
5- Support & Compliance
5.1- Troubleshooting & FAQ
Clear CMOS
If your unit fails to boot or power on, a CMOS reset may help. You will need to open the unit to perform the reset. This does not void your warranty, however, any damage caused by doing so will not be covered. Ensure your body is discharged of any static electricity by touching a grounded metal surface.
Follow the Internal Access guidance.
Locate the jumper shown below.

The top jumper will clear the CMOS

Use needlenose pliers or your fingernails to grab the jumper and remove it from the pins.

Reinstall the jumper as shown and leave in place for 30 seconds.

Restore the jumper to its original position.

Replacing the CMOS battery
Follow the Internal Access guidance
The CMOS battery is held in by a light adhesive. Pull the battery off the board and take care not to damage any components on the board.
Pull the wire straight up to unplug the battery from the board.

Plug the new battery into the board.
Peel off the adhesive and stick in place to eliminate movement.
The BIOS settings and time will be reset when the unit is powered back on.

Ubuntu boots up slowly/Doesn't turn off completely
If you are having issues with Ubuntu randomly crashing, taking several minutes to boot up, or an issue with not fully turning off, try Enabling the PinCntrl Driver GPIO Scheme:
Access the BIOS by pressing DEL while the system is booting up.
Enable Expert Mode under Advanced

Enable Pin Control Driver GPIO Scheme: Advanced/ RC AdvancedMenu/ PCH-IO Configuration/ PinCntrl Driver GPIO Scheme / Enabled
Press F10 to Save & Exit
Preparing for Ubuntu Installation
While Ubuntu Linux is supported on the HX3XX series platform, in order to enable the on-board Programmable Services Engine (PSE) , the following BIOS update must take place.
Step 1: Enter the BIOS and Enable Expert Mode

Step 2: Enable Pin Control Driver GPIO Scheme
Advanced/RC Advanced Menu/PCH-IO Configuration/PinCntrl Driver GPIO Scheme = Enabled

Step 3: (Optional) Re-Disable Expert Mode
Advanced/Expert Mode = Disabled
For further support on Ubuntu Linux please refer to this resource: Ubuntu Linux - first login and reinstallation
PXE Boot Issue
To support PXE (network boot), update your system to the latest BIOS revision available. Note that any operating system booted over PXE will also need Ethernet drivers in order to function.
Frequently Asked Questions (FAQ)
Errata (Known Issues)
IP-1: RS422 and RS485 Require SerCx2:
Description: On Windows, RS422/485 modes require the
SerCx2.sys
driver framework, which is not supported by all serial utilities.Workaround: A UART Sub-Device driver is available for download to map to the
Serial.sys
framework, though it has limitations (e.g., no DTR/DTS line support).
IP-2: System May Power On After Power Interruption:
Description: The system may power on unexpectedly after an input power brownout or glitch.
Resolution: Investigating.
IP-3: Wake-On-LAN Does Not Function:
Description: The Wake-On-LAN feature does not wake the system from any power state.
Resolution: Investigating.
5.2- Regulatory
CE
This device has been tested to the relevant EMC and Safety standards. Modifications by the user may invalidate certifications. Testing included EN 55032, EN 55035, EN 60601-1, EN 62368-1, and IEC 60945 Ed. 4.
FCC Statement
This device complies with part 15 of the FCC rules as a Class A device. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
ISED (Innovation, Science and Economic Development Canada)
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
CAN ICES-003(A) / NMB-003(A)
UKCA
The computer system was evaluated for medical, IT equipment, automotive, maritime and railway EMC standards as a class A device. The computer complies with the relevant IT equipment directives for the UKCA mark.
VCCI
This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI). If this equipment is used in a domestic environment, radio interference may occur, in which case the user may be required to take corrective actions.

Download Documents
5.3- Security Advisory
For the latest security advisories concerning OnLogic products, including vulnerability disclosures and necessary updates, please refer to our official Security Advisories page. It is recommended to regularly check this resource for critical security information. Access Security Advisories
5.4- Appendices
Revision History
Revision History
Date
First release of HX300 manual
8/4/2021
Update errata list
8/12/2021
Update including radio transmitter info, VCCI, RF, Safety info, and power supply info
1/25/2022
CEC Module Removal
04/21/2022
Updated Drawings
05/13/2022
Update Graphs & Appendices
07/28/2022
Updating SIM Slot Info
09/15/2022
Update errata list
01/10/2023
Serial Port Clarification
4/27/2023
VESA Wall Mount Correction
6/7/2023
IO Clarification
7/3/2023
COM and CAN Pin Update
12/02/2024
Last updated